PPAP: what it is and how 3D scanning speeds up dimensional results

PPAP (Production Part Approval Process) is the package of evidence that the supplier delivers to the customer to prove that the actual manufacturing process produces parts conforming to the design, at the planned rate. The dimensional results are the most laborious part of the package, and this is where 3D scanning saves time.
PPAP was born in the automotive supply chain, but today it is also required by machinery, electronics, and other manufacturers that buy parts from suppliers. Below, the process is summarized in a few lines, and the focus is on what generates the most rework: the dimensional study.
What is PPAP and when is it required?
PPAP is described in the manual of the AIAG (Automotive Industry Action Group), now in its 4th edition. It defines what the supplier must demonstrate and how the customer approves the part before series supply. Many OEMs and system suppliers add their own requirements, which prevail over the manual.
Submission is generally requested in these situations:
- a new part or a new version of an existing part;
- a change in design, specification, or material;
- a new, transferred, refurbished, or replaced tool;
- a change in process, production location, or subsupplier;
- correction of a nonconformance on an already approved part.
What is the relationship between APQP and PPAP?
APQP (Advanced Product Quality Planning) is the development method that takes the part from concept to production. PPAP is the validation step of that work: it gathers the evidence generated during APQP, such as FMEA, control plan, and capability studies, and submits it for customer approval.
What are the 18 PPAP elements?
The manual lists 18 elements. Not all are sent in every submission, but all must exist and be available.
- Design records (drawings and models)
- Engineering change documents
- Customer engineering approval, when required
- Design FMEA (DFMEA)
- Process flow diagram
- Process FMEA (PFMEA)
- Control plan
- Measurement system analysis (MSA)
- Dimensional results
- Material and performance test results
- Initial process studies (capability)
- Qualified laboratory documentation
- Appearance approval report, when applicable
- Production part samples
- Master sample
- Checking aids
- Customer-specific requirements
- Part submission warrant (PSW)
What changes between PPAP submission levels?
The level defines what goes physically to the customer and what stays on file at the supplier. The manual describes five levels:
- Level 1: only the PSW (and the appearance report, when applicable).
- Level 2: PSW, samples, and limited supporting data.
- Level 3: PSW, samples, and complete supporting data. This is the default level when the customer does not specify another.
- Level 4: PSW and other requirements defined by the customer.
- Level 5: PSW, samples, and complete data, reviewed at the supplier's manufacturing site.
At any level, the dimensional results must be ready. The difference is whether they will be sent or audited at the factory.
What goes into the PPAP dimensional report?
The dimensional report proves that all characteristics in the design record and the control plan were measured and are within tolerance. In practice, it includes:
- Ballooned drawing: each dimension, geometric tolerance, and note receives a number, which appears in the report.
- Actual measured values: the numerical result of each characteristic, not just "OK" or "conforming."
- Coverage of each process: results for each cavity, mold, die, pattern, or production line. A four-cavity mold requires parts from all four.
- Quantity defined by the customer: the number of parts measured per cavity or process is usually in the customer-specific requirements.
- Identification of method and instrument: how each characteristic was measured, tied to the MSA study.
On a plastic or stamped part with dozens of dimensions, freeform surfaces, and several cavities, this report consumes days of CMM time and data entry. That is where scanning comes in.
How does 3D scanning speed up PPAP dimensional results?
The 3D scanning captures the part's complete surface in a single session. Measurement stops being point by point and is done in the software, on the point cloud or the mesh.
Complete capture instead of dimension by dimension
Once scanned, the part is recorded in its entirety. If the customer asks for a dimension that was not in the plan, it is measured in the file, without returning the part to the machine. This helps especially on freeform surfaces and profiles, which are slow to measure by contact.
Comparison with the CAD and color map
In Geomagic Control X, the cloud is aligned to the nominal model using the drawing's datums and compared in a color map. The map shows warpage, sink marks, or springback that isolated dimensions do not reveal, and makes it easier to explain to the customer a deviation that is under analysis.
Same routine for all cavities
The inspection routine (alignment, dimensions, geometric tolerances, and report format) is built on the first part and reapplied to the others. Comparing cavities side by side becomes immediate, which also helps correct the mold before submission. The approval of molds and stamping dies follows the same logic.
Traceable report
The report comes out with the balloon number, nominal, tolerance, measured value, and status of each characteristic. The article on 3D inspection with GD&T and deviation report details the alignment methods and how this document is assembled.
Where does the 3D scanner not replace other methods?
Scanning speeds up most of the dimensional work, but not every characteristic. Watch out for these cases:
- Very tight tolerances: the measurement system's uncertainty must be small relative to the tolerance. If the tolerance approaches the scanner's accuracy, the characteristic should go to the coordinate measuring machine.
- Threads, small and deep holes: the scanner does not see the inside of narrow holes or thread flanks well. Gauges and contact measurement remain necessary.
- The scanner's own MSA: the scanner is a measurement system like any other. A repeatability and reproducibility (R&R) study is what supports its use in PPAP. Under the usual criterion in the AIAG MSA manual, up to 10% of the tolerance is acceptable, from 10% to 30% may be accepted depending on the application, and above 30% is unacceptable.
The most efficient combination is usually a scanner for surfaces, profiles, and medium-sized holes, and contact for what demands lower uncertainty. The comparison 3D scanner or coordinate measuring machine (CMM) helps separate the characteristics.
Step by step to prepare the PPAP dimensional with 3D scanning
- Confirm with the customer the submission level, the number of parts, and the required report format.
- Obtain the drawing at the current revision and balloon all characteristics, including notes.
- Classify each characteristic: scanning, contact, or gauge.
- Run the MSA study of the chosen methods before measuring the submission parts.
- Take the samples from the significant production run, identified by cavity or process.
- Scan with the part temperature-stabilized and fixtured without stresses that deform it.
- Align using the drawing's datums, not just best fit.
- Generate the report with actual values, group the contact results, and review before signing the PSW.
Common mistakes that delay PPAP approval
- Measuring sample parts made outside the production tool or process.
- Forgetting cavities or production lines in the report.
- Using the wrong drawing revision.
- Aligning by best fit when the drawing defines datums.
- Entering "OK" instead of the measured value.
- Using a measurement system without an approved MSA.
For teams that want to do this work in-house, the Geomagic Control X measurement course covers alignment, dimensions, GD&T, and reports.
Frequently asked questions
Is PPAP mandatory?
It is mandatory when the customer requires it in the contract or the supplier manual, which is the rule in the automotive sector. Outside it, it depends on the buyer.
What is the most commonly used PPAP level?
Level 3, which is the default when the customer does not specify another. It includes the PSW, samples, and complete supporting data.
Can the dimensional report be done with a 3D scanner alone?
It can, when all characteristics are within the scanner's capability and the MSA approves the method. With tight tolerances, threads, or small holes, combine it with contact measurement.
How many parts do I need to measure for PPAP?
It depends on the customer's requirements. The manual requires results for each cavity, mold, die, or process, and the customer defines the quantity per item.
If your company needs to deliver the dimensional for a PPAP on a short deadline, Technosim does the scanning, the digital inspection, and the report by characteristic. Request a quote.